    This happens when the neutral goes out in a house. Usually the waterlines will handle it, but if the house has pex the ground will go through the gas lines.

    Especially if a high voltage line comes down on a gas meter for whatever reason.

    Definitely run away and call professional… everyone i guess.

    • @bobs_monkey@lemm.ee
      link
      fedilink
      119 months ago

      We found out a while ago that plumbing pipes aren’t the best way to ground a house for a variety of reasons, and this is why ufers (grounding to foundation steel) and ground rods are now the NEC standard. Also, this is why bonding wires are important as well. If the plumbing were bonded to a proper dwelling ground system, the current would find a direct path to ground and trip the responsible breaker, instead of using the gas lines as a big ass resistor and creating the light show we see here.

    • @David_Eight@lemmy.world
      link
      fedilink
      59 months ago

      I’ve never seen pex running into a house from the street/ground. It’s always been copper up to the water meter at the very least and it’s code (in NJ at least) to put grounding wire there.

    • @Anivia@feddit.org
      link
      fedilink
      39 months ago

      This would have also been prevented if the electrical install included an RCD. It would have tripped instantly when the neutral gets disconnected

      • @bobs_monkey@lemm.ee
        link
        fedilink
        19 months ago

        Better yet to just have a bond to the gas and water pipes. In this instance, any current introduced to the plumbing has a direct connection to ground, which will allow current to flow freely and trip the breaker.

    • @Asifall@lemmy.world
      link
      fedilink
      19 months ago

      Shouldn’t everything be grounded through the panel as well? I know I have a ground wire running out to a copper plate in the ground next to my house and my understanding was that if the neutral goes that would serve as the path to ground. Is this house missing that feature or am I wrong?